Fixed issue with Target RA and Dec loosing precision

This commit is contained in:
2019-05-08 17:45:42 +01:00
parent 6a4c08a7c4
commit fed8b1a24b
@@ -395,13 +395,14 @@ namespace ASCOM.MeadeAutostar497.Controller
if (_targetRightAscension == INVALID_PARAMETER) if (_targetRightAscension == INVALID_PARAMETER)
throw new ASCOM.InvalidOperationException("Target not set"); throw new ASCOM.InvalidOperationException("Target not set");
var result = SerialPort.CommandTerminated(":Gr#", "#"); //var result = SerialPort.CommandTerminated(":Gr#", "#");
//:Gr# Get current/target object RA ////:Gr# Get current/target object RA
//Returns: HH: MM.T# or HH:MM:SS ////Returns: HH: MM.T# or HH:MM:SS
//Depending upon which precision is set for the telescope ////Depending upon which precision is set for the telescope
double targetRa = HmsToDouble(result); //double targetRa = HmsToDouble(result);
return targetRa; //return targetRa;
return _targetRightAscension;
} }
set set
{ {
@@ -437,15 +438,15 @@ namespace ASCOM.MeadeAutostar497.Controller
if (_targetDeclination == INVALID_PARAMETER) if (_targetDeclination == INVALID_PARAMETER)
throw new ASCOM.InvalidOperationException("Target not set"); throw new ASCOM.InvalidOperationException("Target not set");
var result = SerialPort.CommandTerminated(":Gd#", "#"); //var result = SerialPort.CommandTerminated(":Gd#", "#");
//:Gd# Get Currently Selected Object/Target Declination ////:Gd# Get Currently Selected Object/Target Declination
//Returns: sDD* MM# or sDD*MMSS# ////Returns: sDD* MM# or sDD*MMSS#
//Depending upon the current precision setting for the telescope. ////Depending upon the current precision setting for the telescope.
double targetDec = DmsToDouble(result); //double targetDec = DmsToDouble(result);
return targetDec;
//return targetDec;
return _targetDeclination;
} }
set set
{ {