Conform Report Hash (V1): B869A2DCAA7DACEB47895197B4418080943EDDCC3D1A49E9DDE97B9B22DF8F7B83DC95D595972C4345F53236103CE33045056F1A6BB068B32F72C080377A2FC1

 
ConformanceCheck ASCOM Device Conformance Checker Version 6.4.63.0, Build time: 18/12/2018 08:58:32
ConformanceCheck Running on: ASCOM Platform 6.4 SP1 6.4.1.2695
 
ConformanceCheck Driver ProgID: ASCOM.MeadeGeneric.focuser
 
Error handling 
Error number for "Not Implemented" is: 80040400
Error number for "Invalid Value 1" is: 80040404
Error number for "Invalid Value 3" is: 80040405
Error number for "Value Not Set 1" is: 80040402
Error number for "Value Not Set 2" is: 80040403
Error messages will not be interpreted to infer state.
 
19:18:30.690 Driver Access Checks              OK       
19:18:31.351 AccessChecks                      OK       Successfully created driver using late binding
19:18:31.676 AccessChecks                      OK       Successfully connected using late binding
19:18:31.682 AccessChecks                      INFO     The driver is a .NET object
19:18:31.687 AccessChecks                      INFO     The AssemblyQualifiedName is: ASCOM.Meade.net.Focuser, ASCOM.Meade.net.Focuser, Version=0.4.0.0, Culture=n
19:18:31.692 AccessChecks                      INFO     The driver implements interface: ASCOM.DeviceInterface.IFocuserV3
19:18:32.341 AccessChecks                      INFO     Device does not expose IFocuser interface
19:18:32.405 AccessChecks                      INFO     Device does not expose IFocuserV2 interface
19:18:32.675 AccessChecks                      INFO     Device exposes IFocuserV3 interface
19:18:32.793 AccessChecks                      OK       Successfully created driver using driver access toolkit
19:18:32.967 AccessChecks                      OK       Successfully connected using driver access toolkit
19:18:33.031 AccessChecks                      OK       Successfully disconnected using driver access toolkit
 
Conform is using ASCOM.DriverAccess.Focuser to get a Focuser object
19:18:33.103 ConformanceCheck                  OK       Driver instance created successfully
19:18:33.621 ConformanceCheck                  OK       Connected OK
 
Common Driver Methods 
19:18:33.661 InterfaceVersion                  OK       3
19:18:33.691 Connected                         OK       True
19:18:33.719 Description                       OK       Meade Generic
19:18:33.749 DriverInfo                        OK       Information about the driver itself. Version: 0.4
19:18:33.778 DriverVersion                     OK       0.4
19:18:33.807 Name                              OK       Meade Generic
19:18:33.836 CommandXXX                        INFO     Tests skipped
19:18:33.842 Action                            INFO     Conform cannot test the Action method
19:18:33.850 SupportedActions                  OK       Driver returned an empty action list
 
Properties 
19:18:33.962 Absolute                          OK       False
19:18:33.970 IsMoving                          OK       False
19:18:33.977 MaxStep                           OK       7000
19:18:33.985 MaxIncrement                      OK       7000
19:18:33.994 Position                          OK       Position must not be implemented for a relative focuser and a PropertyNotImplementedException exception was generated as expected
19:18:34.003 StepSize                          OK       Optional member threw a PropertyNotImplementedException exception.
19:18:34.011 TempCompAvailable                 OK       False
19:18:34.019 TempComp Read                     OK       False
19:18:34.027 TempComp Write                    OK       Temperature compensation is not available and a PropertyNotImplementedException exception was generated as expected
19:18:34.036 Temperature                       OK       Optional member threw a PropertyNotImplementedException exception.
 
Methods 
19:18:34.085 Halt                              OK       Focuser halted OK
19:18:34.096 Move - TempComp False                      Moving by: 700
19:18:34.808 Move - TempComp False                      Asynchronous move found
19:18:34.818 Move - TempComp False             OK       Relative move OK
19:18:34.830 Move - TempComp False             INFO     Returning to original position: 0
 
Conformance test complete 
 
No errors, warnings or issues found: your driver passes ASCOM validation!! 
 
Driver Hash Value: 1816E24C06CF16B84021B2B07D4629C3E46DCC5E738D9BACBD524BE5A969BCB07AB3704AB754BC5AA54F5A76F77721D6F7D756AC16DC0AC7DACDC9EA900FA3C8